Analyse du degré de pénétration (80/100)
| Property | Unit | Requirement | Test method |
| Density@ 25 ᵒC | Kg / m3 | 1010-1050 | ASTM D7 or D3289 |
| Penetration @ 25 ᵒC | mm/10 | 80-100 | ASTM D5 |
| Softening point | ᵒC, min. | 45-52 | ASTM D36 |
| Ductility @ 25 ᵒC | cm, min. | 100 | ASTM D113 |
| Loss on heating | Wt %, max. | 0.5 | ASTM D6 |
| Drop in penetration after heating | %, max. | 20 | ASTM D5 |
| Flash point | ᵒC, min. | 232 | ASTM D92 |
| Solubility in Trichloroethylene | Wt %, min. | 99.5 | ASTM D2042 |